Superior coupling · Best optical quality · Versatility

CLASSIC G / Q-LAS

Superior Coupling

The best solution for a combination unit with coagulation laser and photodisruptor on one slit lamp, is using the Haag slit lamp with A.R.C. coupling. The unique fiber coupling of the coagulation laser with the Haag-Streit slit lamp offers true coaxial beam delivery of slit lamp light, laser and aiming beam.

The best optical quality for diagnosis and treatment

Versatility

Diagnosis and treatment on the same slit lamp, one after each other, is only possible with the A.R.C. coupling without any loss in optical quality just by a quick switch. The Classic laser can be easily removed from the system and taken to the operation room for endo coagulation. Optional battery supply makes the system independent from any main supply. Two fiber ports and the unique click fiber system for endo probes provide an easy and simple utilization for any user

Full mobility and easy application

Controlled Power + Energy

The CLASSIC laser provides a superior power output control, which maintains the power output exactly on the demand. The laser light is measured before the laser power can be released to the patients eye. The Q-LAS laser energy is checked every time the energy settings are changed. This provides controlled capsulotomies with adequate energy deposition.

Controlled coagulation and capsulotomies

Optical path (schematic)

Nd:YAG - KTP – Combination

Haag Streit BQ 900 slit lamp

Magnification changer 6.3x 10x 16x 25x 40x
Ocular magnification 12.5x
Objective lens focal length 105 mm
Interpupillary distance 52 – 78 mm
Slit image width 0 - 8 mm continuous
Slit image length 1 - 8 mm continuous
Illumination field diameter 8, 5, 3, 2, 1, 0.2 mm
Slit image radial range ± 90°
Radial movement of the slit Illumination
relative to the microscope axis horizontal
± 90°, vertical 0 – 20°
Filters blue, redfree (green), grey (10%), heat absorption filter
Light source light bulb 6V / 4.5A
Illumination intensity 0 – 600 000 Lux (0V – 7.5 V)
Adjustment of the instrument base 80 mm (length), 30 mm (height), 100 mm (side)

Classic G laser

Laser Diode pumped, frequency doupled Nd:YAG
Wavelength 532 nm
Output power > 1.5 Watt
Pulse rates adjustable 20 ms to CW
Repetition rates 1 - 5 Hz
Spot size 50 - 500 µ, zoom optic
Aiming beam Laser diode 640 nm, red - adjustable intensity
Weight 3.3 kg
Dimensions 250 x 190 x 52 mm
Input Voltage Rechargeable batteries or 90 - 230 VAC

Q-Las 10

Laser Nd: YAG
Wavelength 1064 nm
Mode structure Quasi Gauss
Focus spot in air < 8 microns
Cone angle 16°
Repetition rates 1 pulse per second
Pulse length < 4 ns
Plasma formation in air < 4 mJ
Q-Switch mode Passive
Cooling Air
Output energy 25 mJ max. at 3 Pulses
Energy adjustable in 10 steps: 0.5 - 0.7 - 1.0 - 1.3 - 1.6 - 2.0 - 3.0 -5.0 -7.0 -10.0 mJ in 10 steps
Burst mode adjustable Steps x 2 or x 3
Aiming beam Dual diode beam 635 nm
Micro-offset posterior: 0 - 150 - 300 µ
Power requirements 250 W
Voltage requirements 85-260 V~

CLASSIC G / Q-LAS for...